When safe storage is not enough: building resilience into cell bank infrastructure

22 oktober 2026

Photo: Sub-zero temperatures with long-term effects: Liquid nitrogen at −196 °C forms the basis for the cryogenic storage of sensitive biological materials.
Credit: BioKryo

As biopharmaceutical production scales up, cell banks face growing demands for storage capacity, traceability and reliable access to biological materials. Ensuring long-term security requires more than suitable storage conditions: robust monitoring, qualified transport solutions and contingency plans are essential to protect critical materials against disruptions. BioKryo’s experience illustrates how resilience can be built into cell bank infrastructure.

Monitoring temperatures, documenting inventories, storing samples: The processes of a cell bank follow established routines. But the scale at which they must operate changes as production moves toward commercialization. Clinical development programs evolve into commercial production structures. Material volumes grow, and more samples must be stored securely while remaining reliably available. Additional storage space alone cannot solve this challenge. As production grows, the logistics system behind it must grow as well. The entire process must therefore be considered—from storage and the safeguarding of cell material through to transportation. This brings one concept increasingly into focus: resilience.

Setting new standards for the cell bank

Resilience describes the ability to absorb stress, adapt to changing conditions, and remain capable of acting. While the concept may not immediately be associated with industrial production, it has long been relevant to the pharmaceutical industry. Supply chains must function even during bottlenecks, production processes must respond to changes, and critical materials must remain available. This concept is also becoming increasingly important for biomanufacturing infrastructure. Its importance becomes particularly clear as research and development transition into commercial production.
BioKryo’s practical experience shows how quickly this can become a concrete challenge. The company specializes in the long-term storage of biological materials. However, the work does not begin at the cryogenic tank or freezer. Sample management, for example, involves determining the appropriate storage conditions for each material and ensuring that its storage, assignment, and location remain traceable—even over many years. Logistics is also part of this system. This becomes relevant, for example, when materials already in storage need to be transferred to another location for safe long-term storage.
Cell banks have always had to meet high safety and quality standards. What has changed is not the responsibility itself, but the scale at which it must be managed. This requires additional storage capacity as well as monitoring and sample management systems that can scale accordingly. A particular challenge lies in the materials already in storage. These materials continue to be needed for research, therapeutic applications, or subsequent production steps and must remain available under the specified conditions, even during expansions or restructuring. The challenge is similar to that faced in supply chains: operations must continue while new capacity is added and existing structures are adapted in parallel. This is where resilience becomes critical: changes must be possible without compromising the safety or functionality of existing processes.

Not every sample is the same

This is evident, for example, in cell banks, which serve as a fixed starting point for further production steps. The cell material stored there has been specifically cultivated, examined, and documented and cannot be arbitrarily replaced by another cell sample. If it is unavailable, the very material upon which subsequent manufacturing steps rely may be missing.
However, not all biological material is stored for immediate use in production. Research and the development of new therapeutic approaches may also require long-term storage. In these cases, the material may derive its value from being part of a collection built up over many years or from its role in a long-term research project. A loss would then affect not only the individual sample but could also compromise work already completed and the further use of findings obtained to date. There is therefore no single answer to the question of which safeguards are required for an entire cell bank inventory. What is needed are solutions tailored to the function and requirements of the specific material while remaining integrated into an overarching safety concept.

Putting all your eggs in one basket?

Within a single storage facility, potential disruptions can be mitigated at multiple levels. If, for example, a single storage unit fails, sufficient spare capacity must be available to transfer the affected samples to another system under the required conditions. The additional safeguards required also depend on the storage technology in use. A basic distinction can be made between mechanical deep-freeze storage and cryogenic storage.
In mechanical deep-freeze systems, an electrically powered refrigeration unit generates temperatures as low as −80 °C. If the power supply fails, cooling must therefore be maintained by other means, such as an independent emergency power supply. For samples that must be stored at even lower temperatures, cryogenic storage is used. Liquid nitrogen (LN₂), with a temperature of −196 °C, provides the necessary cold. Depending on the storage system, the samples are located either in the liquid phase or in the cold gas phase above it. It is therefore crucial that LN₂ remains available continuously and in sufficient quantities.
These measures can mitigate individual equipment failures. But what happens when the problem extends beyond a single storage unit and affects the shared infrastructure itself? In this case, the existing measures may reach their limits. For selected materials, it may therefore make sense to create an additional layer of security through geographically separate storage. At BioKryo, such backup structures are used to ensure that critical materials for research and production are not dependent on a single location. However, for this separation to actually work in an emergency, more must be addressed than simply the question of where the at-risk samples are stored. The “how” must also be addressed long before the need for action arises. After all, the materials must reach their secondary storage location under controlled conditions without their quality being compromised along the way.

The critical hours in between

Before the first sample is loaded for transport, more than just its destination must be defined. The receiving storage system and the temperature required for continued storage must be defined in advance. The corresponding storage location must be available and prepared so that the sample can be stored under controlled conditions without unnecessary delay upon arrival. At BioKryo, the designated deep-freeze units are therefore allocated as part of the transport planning process.
Storage conditions determine the requirements that transportation must meet. For example, material stored at −80 °C requires a different temperature management strategy during transport than cryogenically stored samples. The transport system must therefore not only achieve the required conditions but maintain them consistently throughout the entire journey.
Whether it’s a planned transfer or an emergency, it must be established in advance that the transport solution meets the samples’ requirements. BioKryo therefore tests the temperature behavior of transport systems before they are put into use. This includes test runs that examine various positions where the samples may later be located. This is because the temperature within a transport container is not necessarily exactly the same at every point. It is therefore crucial to determine what temperatures occur at the respective positions and how they change over the course of transport. When qualifying a Vault Shipper, for example, BioKryo used seven temperature sensors inside the container and one on the outside. Over a period of 100 hours, tests were conducted to verify whether the intended temperature range of −60 to −65 °C could be achieved and subsequently maintained at the various locations. Based on the results, it is then possible to assess whether the transport container meets the requirements for use.
Once it has been determined which transport container is suitable for the specific material, it must be prepared for use. In the case of the Vault Shipper, this means bringing it to the required temperature before loading it with approximately 200 kilograms of dry ice blocks. Temperatures between −60 and −65 °C are reached inside the container. Once the previously tested conditions have been established under practical conditions, the samples are removed from their previous storage system and transferred to the prepared transport system. From that point onward, the container must maintain the required temperature conditions until the samples reach the new location. Temperature conditions are monitored continuously throughout transport to verify that these requirements are met. To this end, the temperature is continuously recorded. This creates a temperature log that can later be used to track the conditions to which the samples were exposed during the entire journey.
Before the samples are transferred to the appropriate storage system at the new location, the packaging is inspected for possible damage. If no defects are found, the samples are placed into storage. However, before the process can be marked as complete, one final, important step remains. The temperature data recorded during transport is finally evaluated and verified. Only when it is ensured that not only the packaging but also its contents have remained undamaged can the job be marked as complete.

When routine is not enough

Once the material is in place, the transfer process ends, but the safeguarding of the samples does not. With cell banks, one thing is particularly important: vigilance. Everything can function properly for years, and no changes may be detectable from the outside. However, this must not lead to a false sense of security. Behind the scenes, continuous and comprehensive monitoring must ensure that the specified conditions are still being maintained. As soon as a deviation is detected, a response must follow.
For this reason, the storage service provider uses multi-level alarm systems. For the −80 °C deep-freeze units, for example, two independent alarm systems are in use. Redundancy provides an additional layer of protection. If one alarm system fails, the other can take over. If a deviation is detected, the alert is sent to the on-call team via a central notification system. The on-call team can respond immediately and take the necessary steps to restore stable storage conditions. This rapid response is essential to minimize the risk of sample damage as much as possible.


System put to the test

Samples are stored. Monitoring is active. On-call staff are available. Taken together, these measures can make secure storage appear almost routine. Yet this apparent routine should not obscure what ultimately underpins long-term security: resilience. A cell bank is not automatically secure. Like many other areas in medicine and research, the long-term storage of biological materials requires careful planning and a high degree of responsibility.
Precision determines safety at every step. What is crucial, however, is an approach that goes beyond the individual stages and anticipates potential disruptions from the outset—one that has solutions ready and prepares alternative paths before they are needed. Ultimately, it is not day-to-day operations that determine whether a bank is secure; it is tomorrow’s challenges that put a system to the test.

Bron: Air Liquide Germany